Introduce
Wet film thickness (WFT) is the measure of the thickness of an applied paint or covering before it dries. Wet Film thickness is utilizing a Wet Film Thickness Gauge. Wet Film Thickness Gauges give a modest, fast and simple technique to quantify the thickness of coatings following application. They can be utilized over an enormous wet film thickness range, from thick defensive coatings to thin curl coatings. Wet film measures can be utilized on basically any substrate.
Wet Film Thickness Gauges are intended to rapidly and effectively measure paint and covering thickness following application and prior to restoring. They are ordinarily known as Wet Mil Gauges, WFT Gauges, Combs, Comb Gauges, Mil Gauges, Step Gauges and Notched Gauges. They join a progression of scores similar as the teeth on a brush. The wet film thickness of uncured applied coatings including paints, rooftop coatings, powder coatings, intumescent coatings, gel coats, wood coatings, and so forth are effortlessly estimated with a Wet Film Thickness Gauge.
Wet covering thickness estimation or wet film thickness estimation assists the implement with guaranteeing that the covering is applied as per the producer’s details. Applying a lot covering can create many issues, including abundance drying time, dissolvable capture, breaking, drooping, and overabundance covering material expenses. Applying too little thickness can bring about the need to apply extra covers, untimely covering disappointment, inappropriate stowing away, unfortunate appearance, and a large group of different issues that at last can prompt extra time necessities to get done with the task, as well as cases against the utensil and lost benefits.
Wet film thickness ought to be estimated by implements just after the covering is applied, before huge dissolvable dissipation happens to guarantee right estimations. Indeed, even slight postponements in estimating could bring about mistaken low readings, since solvents might have vanished from the film before the estimations were made. Numerous readings ought to be made all through the application interaction to guarantee that the WFT is reliable on all pieces of the covered surface. Consequently WFT gages are for the most part utilized by tools rather than monitors.
Wet covering thickness ought to be observed habitually to keep up with and guarantee a reliable covering process that is as per the producers details. It likewise assists with controlling the expense of the covering as well as application time, working on generally effectiveness and benefit for the instrument. Splash weapon speed, number of passes and shower tips can be acclimated to apply the ideal measure of covering to meet the predefined wet film thickness and eventually the predetermined dry film thickness, which can then be estimated by a dry film thickness check.
It is feasible to anticipate inexact dry film thickness by estimating wet film thickness. Dry film thickness can be determined by utilizing the proportion of solids to fluids. For instance while a covering contains 80% solids and 20% fluid, as the covering dries the fluid vanish, leaving just the solids in the dry film. Along these lines, assuming that the wet film thickness is 100 µm, the dry film thickness will be 80 µm (100 µm x 80% = 80 µm). Dry film thickness, or DFT is the thickness after all of the fluid has dissipated. DFT = WFT x % solids. By essentially turning around the situation DFT can likewise be estimated to figure out what the applied WFT was.
Standards | ISO2808 |
Range | 25~3000µm / 1~118mil |
Value | 25, 50, 75, 100, 125, 150, 175, 200, 225, 250, 275, 300, 350, 400, 450, 500, 550, 600, 650, 700, 750, 800, 850, 900, 1000, 1100, 1200, 1400, 1600, 1800, 2000, 2200, 2400, 2600, 2800, 3000µm |
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 14 ,16, 18, 20, 22, 24, 26, 28, 30, 31, 33, 35, 39, 43, 47, 55, 63, 71, 79, 87, 94, 102, 110, 118mil |
Error: Contact form not found.
Reviews