Brand: CL
Model: MCT-600
Pictures are for reference only.
Power Supply, is a state-of-the-art solid-state, regulated power supply for operating low power Klystrons. It incorporates a number of proprietary.
Specification:
Regulated Beam Supply and Repelled Supply voltages. LED Digital meter for Beam voltage, current and Repelled voltage. Compact and Reliable. Modular construction for easy maintenance. In addition to AM and FM modulation of beam current, a provision for external modulation is Provided.
Beam Supply:
Voltage: Variable 240 – 420 VDC
Current: 50 mA
Ripple: < 4 m Vrms (ON Load)
Repelled Supply: Variable -18 V to -270 V DC (ON Load)
Filament Supply : Adjustable 6.3 VDC
Over-Load trip current: 65 mA
Digital Panel meter : 2 V
Modulation: AM (Square)
Frequency Range : 500 – 2000 Hz, 0 – 110 Vpp, FM (Saw – tooth)
Frequency Range: 50 – 150 Hz
Amplitude: 0 – 60 Vpp
External: Through External Modulating Signal
Display: Digital display for Beam voltage, Beam Current, Repelled voltage
Modulation Selector: CW/AM/FM/EXT
Meter Selector: Beam Voltage (V)/ Current (I)/ (Repelled) Rep.
Connectors: 8-Pin Octal Socket b. BNC for External Modulation
Power Supply : 220 V ± 10%, 50Hz
VSWR Meter Display: 16 × 2 Characters LCD
Sensitivity: 0.1 mV for 200 W input impedance
Noise Level: Less than 0.02 mV
Range: 0 – 60 dB in 10 dB steps
Input: Un-biased low and high impedance
biased crystal (200 W and 200 K)
Display Select: SWR 1 – 9 dB 0 – 10
Modes: Normal
Audio
PC-Interface
Gain Control: Adjusts the reference level
Variable range 0 -10 dB approx.
Input Connector: BNC (F)
Input Frequency: 1000 Hz ± 10%
Power Supply: 220 V± 10%, 50Hz
Solid Directional Cell:
These are used to measure dielectric constant of any solid material these consists of a cavity for keeping the sample and micrometer to read the position of sample.
Frequency: 8.2-12.4GHz
Max. Length of cell: 100mm
Plunger movement: 25mm
Cross Directional Coupler:
Cross Directional Coupler consists of two waveguide sectional joint at (90°) with the coupling element mounted into the common broad wall.
Frequency: 8.2-12.4GHz
Coupling (dB): 20dB
Coupling accuracy: ±1Db
E-Plane Tee:
Frequency: 8.2-12.4GHz
Max. Length of cell: 200mm
Plunger movement: 65mm
Micrometer Type Frequency Meter:
Micrometer type frequency meters are consisting of a microwave cavity with plunger and a section of waveguide. It consists of a micrometer to measure its position for measuring frequency.
Frequency: 8.2-12.4GHz
Max. VSWR: 1.15
Calibration accuracy: ±2%.
Calibration increment: 10 MHz
Waveguide Antennas:
There are several types of microwave antennas like standard Gain, Paramedical horn, pick up horn, Dielectric antenna, Parabolic dish antenna etc. these are used to radiate microwave energy in the air and to receive the energy from air.
Frequency: 8.2-12.4GHz
Antenna type: Paramedical, Gain: 16
Multi-hole Directional Coupler:
Directional coupler is designed to measure incident and reflected power values and also provide a signal path to a receiver or perform other desirable operation. In its most common form, the directional coupler is a four-fort waveguide junction consisting of a primary main waveguide and a secondary auxiliary waveguide. These are available in 3, 6, 10, 20, 40 dB coupling.
Frequency: 8.2-12.4GHz
Max. VSWR: 1.06 to 10.5 GHz
Return loss: -31 dB at 10.5 GHz
Coupling dB: 10.1±0.6
Variable Attenuator:
Frequency: 8.2-12.4GHz
Max. VSWR: 1.06 to 10.5 GHz
Return loss: -31 dB at 10.5 GHz
Coupling dB: 10.1±0.6
Attenuators:
Attenuators are required to adjust power or attenuate the power flowing in waveguide. There are two types of attenuators fixed and variable. Fixed attenuators available in various range like 3dB, 6dB, 10dB etc. These attenuators are calibrated at center frequency of respective frequency band. By Variable attenuators power can be adjusted for different level.
Frequency: 8.2-12.4GHz
Max. VSWR: 1.06 to 10.5 GHz
AV Power: 2W
Accuracy: ±0.5dB
Return loss: -31 dB at 10.5 GHz
Direct Reading frequency Meter:
Direct Reading frequency meters are used to measure the microwave frequency accurately. There long scale length and numbered calibration marks provide high resolution which is particularly useful when measuring frequency difference of small frequency change.
Frequency: 8.2-12.4GHz
Max. VSWR: 1.28 at 10.5 GH
Calibration Accuracy: ± 2%
Calibration increment: 5 MHz
Return loss: -18.2 at 10.5GHz
Wave Guide Adaptor:
Adaptors transform waveguide impedance to coaxial impedance. Adopters consist of a short section of waveguide with a probe transition mounted on broad wall. Power can be transmitted in either direction. Each adaptor covers the 50% of the waveguide.
Frequency: 8.2-12.4GHz
Connector: N Type
Max. VSWR: 1.12 at 10.5 GHz
Return loss: -24.5 at 10.5GHz
Tunable Probe: Tunable probes are very useful devices to measure the SWR and Impedances. Tunable probe is consisting of a Continue From Above crystal detector and a small wire antenna in coaxial housing. Its depth of penetration into the slotted section is variable.
Frequency: 8.2-12.4GHz
Detector: IN23
Tunable type
Klystron Mount: Klystron mounts are used to transmit microwave