Brand: CL
Model: OWON DS4000
Pictures are for reference only.
Features:
- Min. 7-inch WVGA color display with 15 horizontal divisions that shows 50% more signal
- Min. 32 automated measurements
- Dual window FFT with simultaneous time and frequency domain views
- trigger frequency counter
- Pan and Zoom capability
- Multi-language user interface with support for 10 languages in the user interface and front panel overlay
- Small footprint and light weight
- Fanless design contributes to low noise operation
- Electromagnetic compatibility: EC Council Directive 2014/30/EU
- Safety: comply with the Low Voltage Directive 2014/35/EU for Product Safety
Specification:
- Bandwidth: Min. 100 MHz
- Channels: min. 2
- Sample Rate: 1 GS/s
- Record Length: 20 K points
Vertical system – Analog channels:
- Vertical resolution: 8 bits
- Input sensitivity range: 1 mV/div to 10 V/div max. in 1-2-5 sequence with probe attenuation set to 1X
- DC gain accuracy: ±3.0 % step gain, debated at 0.1 %/°C above 30 °C
- Maximum Input Voltage: 300 VRMS, Installation Category II debate above 4 MHz at 20 dB per decade to 200 MHz
- Offset range:
1 mV/div to 50 mV/div: ± 1 V
100 mV/div to 500 mV/div: ± 10 V
1 V/div to 5 V/div: ± 100 V
- Bandwidth limit 20 MHz (Typ)
- Input coupling DC, AC
- Input impedance 1 MΩ ±2 % in parallel with 14 pF ±2 pF
- Vertical zoom Vertically expand or compress a live or stopped waveform Horizontal system Analog channels:
- Time base accuracy: ±25 x 10-6 over any >1 ms interval
- Time base range: 2 ns/div to 100 sec/div in a 1-2-4 sequence
- Horizontal zoom: Horizontally expand or compress a live or stopped waveform
- DE skew range: ± 100 nsec
Trigger system:
- External trigger input: Included on all models
- Trigger modes: Auto, Normal, Single Sequence
- Trigger Types: Edge, Pulse Width, Runt
- Trigger source: CH1, CH2, AUX IN, AC Line
- Trigger Coupling: DC, Noise Reject, High Frequency Reject, Low
Waveform measurements:
- Cursors: Time, Amplitude, Screen
- Automated measurements: 32, of which up to six can be displayed on-screen at any one time.
- Measurements include: Period, Frequency, Rise Time, Fall Time, Positive Duty Cycle, Negative
Duty Cycle, Positive Pulse Width, Negative Pulse Width, Burst Width, Phase, Positive Overshoot, Negative Overshoot, Peak to Peak, Amplitude, High, Low, Max, Min, Mean, Cycle Mean, RMS,
Cycle RMS, Positive Pulse Count, Negative Pulse Count, Rising, Edge Count, Falling Edge Count, Area, Cycle Area, Delay FR, Delay FF, Delay FR, and Delay RR.
- Gating: Isolate the specific occurrence within an acquisition to take measurements on, using either the screen, between waveform cursors or full record length.
Waveform math:
- Arithmetic: Add, Subtract, and Multiply waveforms
- FFT: Spectral magnitude.
- Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Henning, or Blackman-Harris.
Display system:
- Display Type: Min. 7-inch TFT Color Display
- Display Resolution: 800 horizontal by 480 vertical displayed pixels (WVGA)
- Waveform styles: Vectors, Variable persistence, and Infinite persistence.
- Format: YT and XY
Input Output Ports:
- USB 2.0 Host Port: Supports USB mass storage devices
- USB 2.0 device port: Rear-panel connector allows for communication/control of oscilloscope through USBTMC or GPIB with a TEK-USB-488
Probe Compensator:
- Amplitude: 5V
- Frequency: 1 KHz
- Kensington Style Lock: Rear-panel security slot connects to standard Kensington style lock
Power source:
- Power source: 100 to 240 VAC RMS ±10%
- Power source frequency: 45 Hz to 65 Hz (100 to 240 V) 360 Hz to 440 Hz (100 to 132 V)
- Power consumption: 30W maximum
- Dimension (H*W*D): Min. 150*320*105
- Weight: Min. 1.9 kg
- Operating Temperature: 0 ºC to +50 ºC
- Operating Humidity:
5% to 90% relative humidity (% RH) at up to +30 °C
5% to 60% RH above +30 °C up to +50 °C
- Operating Altitude: Up to 3,000 m (9,842 ft.)
Reviews