Brand: CL
Model: SPT-680
Pictures are for reference only.
Features for Protection Relay Experiment Trainer:
- Experiment projects are complete, experiment content is rich, design is reasonable, which are beneficial to broaden the students’ knowledge.
- Experimental device has excellent compatibility and scalability. Experimental installations adopt platform design, laboratory modules using component design.
- Experimental device has strong intuitionist. Each relays is the abdomen – installed on the panel surface, students can clearly see the action of every relay, and are convenient to set relay values. At the same time, the relays and other components electrical diagrams of are painting on each panel, which are complete and consistent teaching materials, can help students understand the book knowledge, improve the experimental results.
- The experiments are strong package, the AC-DC power supply, instrumentation, relay and experimental connecting wire in experiment all fully equipped.
- Experiment has authenticity. The relays used in experiment are relays which are currently using on-site power system, and better reflect the status of the power system, and lay a good foundation to engage in design, installation, debugging, maintenance and other work to for students after graduation for protection system
- Structure is reasonable. The whole structure adopt a three-tier structure, panel ranking according to the actual line with the flow, experimental function block is clarity, carefully designing improve experimenter’s understanding of the system, wiring facilitate and the efficiency of the experiment.
- The experiment device has perfect protection measures. The device provide leakage circuit breakers and other physical security protection measures. Various instruments and power supplies all have a perfect protection function.
Â
Experiment Projects:
Relay Specialty:
- Current relay specialty experiment
- Voltage relay specialty experiment
- Electromagnetic time relay experiment
- Intermediate relay specialty experiment
- Signal relay specialty experiment
- Transistors negative sequence voltage relay experiment
- Impact relay specialty experiment
- Flashlight Relay specialty experiment
- Three-phase reclosing device experiment
- Rectifier direction characteristic impedance Relay experiment.
- Differential relay experiment.
- Power direction relay experiment
- Anti-time over current relays characteristics experiment
Line Protection:
- Over-current protection circuit experiment
- Low voltage start over-current protection and overload protection experiment
- Repeat action of manual revert to central signal device experimental
- Repeat action of manual revert to central audio signal device experimental
- Break control loop experiment with lighting surveillance
- Automatic reclosing accelerated protection experiment
- Automatic reclosing after accelerate protection circuit
- Power direction over current protection experiment
- Anti-time over current protection moves specialty experimental
- Distance protection and direction stage-protection setting experiment
- Unilateral power line Rd radiation-current protection experiments
Technical Specifications of Modules:
Signal Relay:
- Voltage: 220VDC
- NO Contact: 2 sets
Adjustable Single Phase:
- Voltage: 0 ~ 240VAC
- Current: 1A
Bridge Rectifier:
- Voltage: 1000V
- Current: 35A
Universal Change Over Switch:
- Rated Current: 20A
- NO Contacts: 4 sets
Simulate Switch Board:
- Rated voltage: 240VAC
- Push Button X 3 units
- Current Relay:
- Current: 1.25A to 5A
- NO Contact: 1 set
Negative Sequence Relay:
- Input Voltage: L1, L2 & L3
- Voltage: 220VDC
Time Delay Contractor:
- Coil Voltage: 240VAC
- Contact: NO & NC
- Time: 0…60seconds
Intermediate Relay:
- Voltage: 220VDC
- Trigger Current: 1A
- NO Contact: 2 sets
- NC Contact: 2 sets
Phase Analyzer:
- Input: L1, L2 & L3
- To check phase voltage in correct/incorrect sequence
Adjustable Three Phase:
- Protection Fuse 2A x 3 units
- Pilot Lamps L1 , L2 & L3
- Fault Current Circuit Breaker 3 Poles
- Output: 0…240VAC x 3 units; 0…415VAC
- Input: AC 415V, 50Hz 3-Phase
Timer Relay:
- Voltage: 220VDC
- Time: 0.1s to 1.5s
- NO Contact: 2 sets
- NC Contact: 2 sets
Low Voltage Relay:
- Voltage: 40V to 160V
- NO Contact: 1 set
- NC Contact: 1 set
Impulse Relay:
- Voltage: 220VDC
- Current: 0.16A
- NO Contact: 1 set
- NC Contact: 1 set
Synchronous Detector:
- Voltage: 220VDC
- Voltage: Compare: 110VAC
- NO Contact: 1 set
- NC Contact: 1 set
Flashing Relay:
- Voltage: 220VDC
- NO Contac: 2 sets
Overload Relay:
- Current: 8A to 16A
- NO Contact: 2 sets
- Electronic Timer: Start, stop and reset function
Contactor:
- Voltage: 220VDC
- NO Contact: 2 sets
- NC Contact: 2 sets
Rheostat 100Ω/1kΩ:
- Rheostat 1kΩ/100W
- Rheostat 100Ω/100W
Indicator and Buzzer:
- Lamp Voltage: 240VAC
- Buzzer Voltage: 240VAC
Alarm Indicator:
- Voltage: 240VAC
AC Voltmeter:
- Range: 300V & 500V
AC Ammeter:
- Range: 5A & 20A
DC Current & Voltmeter:
- Voltage Range: 300V
- Current Range: 10A
Three Phase Bridge Rectifier:
- Three phase rectifier bridge
- Maximum Voltage: 400VAC
- Maximum current: 10A
Fault Current Circuit Breaker:
- Protection Fuse 2A x 3 units
- Pilot Lamps L1 , L2 & L3
- Fault Current Circuit Breaker 3Poles
- Input: AC 415V, 50Hz 3-Phase
Resistive Load:
- Compose of three resistances with possibility to connect in star/delta or parallel, controlled by three switches with 7 steps variable per phase
- Max Power : 1200 watt
- Voltage : 380/220 Volt (Star/Delta)
- U-LINK: For connecting junction point
- Safety Connecting Lead: 4mm connecting leads
Vertical Frame:
- High level: DIN standard A4 with two shelves
- Material: Aluminum
- Side Frame: T shape
- Size: 3-Layer 1450mm Length
Reviews
There are no reviews yet.