Brand: CL
Model: FD-600
Pictures are for reference only.
- Automative exhaust gas analyser with 6-line display
- Fuel types: Petrol/Gasoline, CNG, LPG, Diesel
Measures:
- CO: 0 – 10,000, CO2: 0 – 20%,
- NOx: 0-600ppm
- Compact and quick to use with large display
- Spot check faulty exhausts and catalytic converters
- Compact design with protective rubber sleeve
- Magnets for hands free operations
- Test Diesel engine NOx emissions
- Test warehouse indoor air quality
- Check vehicle cab heaters
- Rotary dial for ease of use
- Store up to 99 tests
Following Air Quality Tester for Automobile Lab Features:
- The cloud-based air quality monitor that records and displays real-time data for a wide range of parameters, such as particulate matter, pollutant gases, temperature, humidity, and barometric pressure
- With active internet connection, user should be able to monitor this data live from computer or phone
- The monitoring system should be available with four fundamental sensors: particulate matter, temperature, relative humidity (RH), and barometric pressure (BMP)
- Additionally, it should be supplied with minimum two gas sensors
- Supplied configuration rack indoor air quality by detecting PM and identify harmful gases
- It be meticulously designed to withstand extreme conditions, operate reliably in temperatures as low as -20 °C and humidity levels up to 99%
- Suitable for both indoor and outdoor environments
- Integrated Heater for maintaining stable temperature, melting snow, ensuring precise measurements.
- Operate on both WiFi and 4G LTE networks for remote monitoring
- For 4G LTE Network, SIM card
- Quick setup and intuitive cloud dashboard for easy monitoring
- Supply with 32GB microSD card and cloud storage
- Internal data backup during cloud connectivity interruptions
- Should save data to the SD card, even in offline
- Cloud facility to be used for data access, system updates, and firmware tweaks
- Warnings should be displayed in cloud data for SD or cloud upload issues
- Quick Deployment: Ready to roll right out of the box.
- This robust system must be delivered as primed for setup in under 15 minutes
- Reliable Performance: Designed for resilience, guarantee unwavering functionality in temperatures ranging from a chilly-20 to a scorching 50°C.
Technical Specifications:
Particulate Matter Measurements:
- Range: 0 to 1000 µg/m3
- Mass concentration measurements of PM1, PM2.5, PM4 and PM10
- Measurement resolution: 1 µg/m3
- Sensor lifetime: 10 years
Mass concentration accuracy:
- PM1 and PM2.5: 5% (0 – 100 μg/m3) 10% (100 – 1000 μg/m3)
- PM4 and PM10: 25% (0 – 1000 μg/m3)
- Startup time: <60s
- Response time: <30s
- Acoustic emissions level: 24 dBA at 0.2m
- Long term acoustic emission level drift: +0.5 dB(A)/ year
Operating range:
- Temperature: -20 to 50°C
- Relative humidity: 20 – 99% (non-condensing)
- Barometric pressure: 300 – 1200 mbar
Temperature, relative humidity, and barometric pressure measurements:
Temperature:
- Measurement range: -40 to 85°C
- Accuracy: Typical ±0.1°C (0 to 60°C), max. ±0.3°C (-40 to 85°C)
- Resolution: 0.01°C
Relative humidity:
- Measurement range: 0 to 99% (non-condensing)
- Accuracy: Typical ±1%; max. 2% (0 to 90%) and ±3% (91 to 100%)
- Resolution: 0.01%
Barometric pressure:
- Measurement range: 300 to 1200 mbar (30 to 120 kPa)
- Accuracy: ±1 mbar (0 to 65°C)
- Resolution: 0.01mbar
Gas sensors should be included:
Volatile Organic Compound (VOC):
- Sensor output: 0 – 500 VOC Index
- Response time (τ63%): <10s
- Device-to-device variation: <±15 VOC Index points
- Repeatability: <±5 VOC Index points
Carbon Monoxide (CO):
- Measurement range: 0 – 1000 ppm
- Maximum overload: 1000 ppm
- Accuracy: ≤ 2ppm
- Response time: <30s
- Repeatability: <1%
- Lower detectable limit (LDL): ≤2ppm
- Resolution: 0.1 ppm
- Expected lifetime: >5 years in air
- Cross sensitivity: Hydrogen (20 ppm in 100 ppm concentration)
- Operating Temperature range: -40°C to 55°C
- Operating Pressure range: 800 to 1200 hPA
- Operating humidity range: 15 – 95%
Sulfur Dioxide (SO2):
- Measurement range: 0 – 50 ppm
- Maximum overload: 100 ppm
- Accuracy: ≤ 1 ppm
- Response time: <60s
- Repeatability: <1%
- Lower detectable limit (LDL): ≤1ppm
- Resolution: 0.1 ppm
- Expected life time: >3 years in air
- Long-Term Drift: <1% / month
- Operating Temperature range: -40°C to +55°C
- Operating Pressure range: 800 to 1200 hPA
- Operating humidity range: 15 – 95%
Cross sensitivity:
- Chlorine (-1ppm in 10ppm concentration)
- Nitric Oxide (<-3ppm in 25ppm concentration)
- Hydrogen Cyanide (<5ppm in 10ppm concentration)
Ozone (O3):
- Measurement range: 0 – 5 ppm
- Maximum overload: 10 ppm
- Accuracy: ≤ 0.05 ppm
- Response time: <60s
- Repeatability: <2%
- Lower detectable limit (LDL): ≤ 0.05 ppm
- Resolution: 0.01 ppm
- Expected lifetime: > 24 months
- Long-Term Drift: <1% / month
- Operating Temperature range: -20°C to 40°C
- Operating Pressure range: 800 to 1200 hPA
- Operating humidity range: 15 – 95%
- Cross sensitivity: Sulfur Dioxide (1ppm in 5ppm concentration)
Power supply and Enclosure:
- Power supply: AC/DC adapter should be included
- Weatherproof enclosure: Protection from rain and sunlight exposure
- The enclosure should have Top cover, Status LED, Air inlet & outlet facility, Sensor probe connector, Power Jack connector etc.
The status LED blinking should interpret below conditions –
- 0 – Initialize device
- 1 – Normal Operation
- 2 – No internet connection
- 3 – Sensor error
- 4 – Internal backup storage is full
Software:
- Connecting computer or phone:
- Activation of the device by powering it up. Once the LED begins flashing establishment of a connection with a computer or phone will have to be initiated. Wi-Fi settings on computer or phone will have to be accessed and computer or phone will have to be connected using the password as mentioned in the operation manual
- Upon successful connection, the system configuration panel will automatically launch in a browser window. If the window does not appear automatically, user must Open a browser, enter 192.168.4.1 in the address bar and Press “Go”
- its click on the “Configure Wi-Fi” function and choosing of Wi-Fi network from the available Wi-Fi networks list
Configuration:
- Configuration of various settings for the device, such as the device name, user ID or email, time zone, logging interval, and running average for PM data can be done by clicking on Setup
- Device name: The designated name to serve dual purpose: it be employed in the cloud and also appear as the Wi-Fi name when connecting a phone or desktop for configuration
- Time zone: Selection of the suitable time zone and this setting to be used to record time data within the micro SD card
- Log Interval: This feature should allow users to choose their preferred logging interval, ranging from 15 seconds to 1 hour. Available logging intervals should be 15 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min and 1 hour.
- Running Average for PM Data: This configuration determine whether the device use a running average.
- ON: The system collect PM data every second. Upon logging the data, it compute the average for the complete interval
- OFF: In this scenario, the system refrain from averaging the data throughout the entire interval. Instead, it calculate the average of the data from the last 5 seconds of the logging interval and record that specific value.
- Sign in to Cloud: Navigation to Cloud Platform via address mentioned in the operation manual. Come with the landing page that prompts end user for sign-in credentials.
Dashboard Overview:
- After successfully signing in, end user be directed to the dashboard of the Cloud Platform
- The dashboard homepage display a list of connected devices
- Visible connected device show details such as device name, model number, device ID, and subscription information
- Additionally, there be an option to extend or purchase a subscription by
- clicking on the “Buy Subscription” button
- Data Summary: Data Logger” tab in the top left corner be available for the end user so
- that he/she can view the summary of data for a specific device from the list of connected devices on the cloud platform
- After selecting the desired device, a summary of data be displayed on the screen which show the minimum, maximum, and average values of the data stored in the cloud so far Continue scrolling should find the graphical representation of data
- Live Monitoring: Live data monitoring also be accessible directly from the dashboard by clicking on the available “LiveData” tab
Editing Device and Finding Information:
- Minimum three icons be available
- Symbol which be designated for device information.
- Clicking on it open a small window displaying device information.
- End user also receive the information of current firmware version.
- Pen and paper sign icon which is designated for editing the device.
- From here, end user be able to modify logger name, set logging intervals, delete the logger, and erase data.
- Another icon be “download data” icon.
- Clicking on the download icon appear a new window from where data downloading can be done by selecting the date and time. Alternatively, data can be downloaded by selecting from the available time durations listed at the bottom of the data downloading window.
- It should be available in the name of “Quick Download”.
Data downloading from micro SD card w/o removing:
- To do this, user must follow the following steps
- Power off the device if it is currently powered on
- Turn the power back on
- From a computer or phone, search for available Wi-Fi networks
- Look for a network name that starts with the device name and connect to that network
- If prompted, enter the password
- The configuration page should automatically open
- If not, open a browser and type 192.168.4.1 in the address bar
- Click on the “Stored Data” button
- If a micro SD card is present, the files on the micro SD card should be displayed on the screen.
- Download the files onto computer or phone using the browser
Accessories:
Probes and sensors as per configuration, Power adapter, Mounting bracket, Zip ties, Double sided foam tape, Screws, Micro SD card, Royal plugs, Printed operation manual etc.
Reviews
There are no reviews yet.